Senja, Fita Desti and Purba, Elida and Putri, Finka Pertama ABSORPSI GAS CO2 PADA REPLIKA GAS BUANG PLTU TARAHAN MENGGUNAKAN LARUTAN Na2CO3 (VARIASI LAJU ALIR Na2CO3) CO2 ABSORPTIONON REPLICA OF PLTU TARAHAN FLUE GAS USING Na2CO3SOLUTION (Na2CO3FLOW RATE VARIATIONS). PROSIDING SEMINAR NASIONAL BARISTAN 2016.

[img] Text
Baristan Fita Elida.docx

Download (166kB)
[img] Text
ELIDA FITA BARISTAN.docx

Download (167kB)
[img] Text
ELIDA PURBA BARISTAN 2016.docx

Download (283kB)

Abstract

ABSTRAK Penelitian ini membahas tentang proses absorpsi gas CO2 dari replika gas buang PLTU Tarahan dengan menggunakan larutan natrium karbonat (Na2CO3) sebagai absorben. Tujuan penelitian ini yaitu mengetahui pengaruh laju alir larutan natrium karbonat terhadap persentase penyerapan CO2 dan penurunan temperatur gas keluaran setelah proses absorpsi. Hal ini bertujuan agar proses absorpsi dapat diaplikasikan sebagai salah satu solusi untuk pengurangan gas CO2. Penelitian dilakukan dengan metode absorpsi secara kimia menggunakan solven Na2CO3 dan penambahan katalis H3BO3 pada packed column absorber. Variasi laju alir Na2CO3 yang digunakan pada penelitian ini yaitu (1, 1.5, 2, 2.5, dan 3) lpm dengan konsentrasi 25% berat serta laju alir gas sebesar 6 lpm. Analisis sampel dilakukan dengan menggunakan Gas Chromatography 2014-AT SHIMADZU Corp 08128. Dari hasil penelitian yang didapat, semakin besar laju alir maka penyerapan gas CO2 semakin meningkat dengan persentase penyerapan CO2 terbesar yaitu 72.45% pada laju alir 3 lpm. Namun hal ini berbanding terbalik terhadap penurunan temperaturnya. Semakin besar laju alir maka persentase penurunan temperatur semakin kecil. Penurunan temperatur terbesar terjadi pada laju alir yang paling kecil (1 lpm) yaitu dari temperatur 50oC menjadi 36oC dengan persentase penyerapan 28%. Kata kunci: CO2, Na2CO3, Absorpsi Kimia. ABSTRACT This research discusses CO2 absorption on replica of PLTU Tarahan flue gas using sodium carbonic (Na2CO3)solution as absorbent. The purpose of this research is to know the effect of sodium carbonic flow rate variations on CO2 absorption percentage and lowering the output gas temperature after the absorption takes place. Afterwards this absorption can be used as a solution in reducing CO2 concentration. The method used is a chemical absorption with Na2CO3 as solvent and H3BO3 as catalyst in packed column absorber. Flow rates variations are (1, 1.5, 2, 2.5, and 3) lpm with 25% weight concentration as well as gas flow rate 6 lpm. Sample analysis is using Gas Chromatography 2014-AT SHIMADZUCorp 08128. The result of this research is the higher flow rate used, CO2 absorption is increasing and the highest percentage is 72.48% with flow rate of 3 lpm. However in contrast with temperature lowering, the higher flow rate, percentage of temperature reduction will be smaller. The highest point on temperature lowering is on the lowest flow rate (1 lpm) that is from 50oC to 36oC with 28% of absorption percentage. Key word: CO2, Na2CO3, Chemical Absorption.

Item Type: Article
Subjects: T Technology > TD Environmental technology. Sanitary engineering
Divisions: Fakultas Teknik (FT) > Prodi Teknik Kimia
Depositing User: ELIDA PURB
Date Deposited: 02 Jun 2017 12:22
Last Modified: 02 Jun 2017 12:22
URI: http://repository.lppm.unila.ac.id/id/eprint/2873

Actions (login required)

View Item View Item