Warsito, Warsito and Dewanto, Ordas (2007) Analisis Efisiensi Thermistor Sebagai Dasar Realisasi Alat Ukur Konduktivitas Panas. FMIPA Universitas Lampung.

[img]
Preview
Text
20. Plagiarism Checker X, Jurnal MIPA FMIPA Universitas Lampung, Edisi Khusus Fisika 2007, Vol. 13, No. 3, Hal 216-220.pdf

Download (138kB) | Preview
Official URL: https://jurnal.fmipa.unila.ac.id/sains/issue/view/...

Abstract

Thermistor is one of the passive sensor based on the change of resistance value toward the heat change. The respond nonlinearity of thermistor against the heat change has been the weakness of this sensor, but this thermistor has high sensitivity up to 2,43 dT dR Kohm/K. The signal condition series is realized by the use pf two op-amp series which was cascade arranged in order to minimize the internal noise in the level of strengthening. Bu using once strengthening as well as high strengthening will multiple the noise value as much as Atime of strengthening. The result of the design used to measure the rock heat showed that there was an agreement between the result of the measurement and the reference value in the rock which was given by Gretener1) .

Item Type: Other
Subjects: Q Science > Q Science (General)
Q Science > QE Geology
Divisions: Fakultas Teknik (FT) > Prodi Teknik Geofisika
Depositing User: ORDAS DEWA
Date Deposited: 07 Jul 2022 02:42
Last Modified: 07 Jul 2022 02:42
URI: http://repository.lppm.unila.ac.id/id/eprint/43037

Actions (login required)

View Item View Item