Beroual, Abderrahmane and Khaled, Usama and Noah, Phanuel Seraphine Mbolo and Sitorus, Henry (2017) Comparative Study of Breakdown Voltage of Mineral, Synthetic and Natural Oils and Based Mineral Oil Mixtures under AC and DC Voltages. Energies, 10 (511). pp. 1-17. ISSN 1996-1073
|
Text
Henry_energies-10-00511- Cut.pdf - Published Version Download (372kB) | Preview |
Abstract
This paper deals with a comparative study of AC and DC breakdown voltages of based mineral oil mixtures with natural and synthetic esters mainly used in high voltage power transformers. The goal was to analyze the performances of oil mixtures from the dielectric withstand point of view and to predict the behavior of transformers originally filled with mineral oil and re-filled with synthetic or natural ester oils when emptied for maintenance. The study concerns mixtures based on 20%, 50%, and 80% of natural and synthetic ester oils. AC breakdown voltages were measured using a sphere-sphere electrode system according to IEC 60156 specifications; the same specification was adopted for DC measurements since there is no standard specifications for this voltage waveform. A statistical analysis of the mean values, standard deviations, and histograms of breakdown voltage data was carried out. The Normal and Weibull distribution functions were used to analyze the experimental data and the best function that the data followed was used to estimate the breakdown voltage with risk of 1%, 10%, and 50% probability. It was shown that whatever the applied voltage waveforms, ester oils always have a significantly higher breakdown voltage than mineral oil. The addition of only 20% of natural or synthetic ester oil was sufficient to considerably increase the breakdown voltage of mineral oil. The dielectric strength of such a mixture is much higher than that of mineral oil alone and can reach that of ester oils. From the point of view of dielectric strength, the mixtures constitute an option for improving the performance of mineral oil. Thus, re-filling of transformers containing up to 20% mineral oil residues with ester oils, does not present any problem; it is even advantageous when considering only the breakdown voltage. Under AC, the mixtures with natural ester always follow the behavior of vegetable oil alone. With the exception of the 20% mixture of natural ester in DC, the breakdown voltage values of all the tested mixtures were in accordance with the normal distribution, which made it possible to define the breakdown voltages for the risk levels of 1%, 10%, and 50% of probability.
Item Type: | Article |
---|---|
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Fakultas Teknik (FT) > Prodi Teknik Elektro |
Depositing User: | Dr. Henry B.H. Sitorus |
Date Deposited: | 31 May 2017 04:56 |
Last Modified: | 31 May 2017 04:56 |
URI: | http://repository.lppm.unila.ac.id/id/eprint/2240 |
Actions (login required)
View Item |