Hadi, Prayogo and Herri, Gusmedi (2014) Prototype Proteksi Arus Lebih Menggunakan Current Transformer Berbasis Mikrokontroller Atmega32. ELECTRICIAN – Jurnal Rekayasa dan Teknologi Elektro, 8 (3). pp. 189-201. ISSN 1978-6042

[img]
Preview
Text
Prototype Proteksi Arus Lebih Menggunakan Current Transformer Berbasis Mikrokontroller Atmega32.pdf

Download (529kB) | Preview
Official URL: https://electrician.unila.ac.id/index.php/ojs/arti...

Abstract

Intisari -Sistem proteksi pada peralatan tenaga listrik sangat diperlukan untuk menjaga kehandalan dan kualitas listrik, sistem proteksi yang baik mampu melokasilisir keadaan dari gangguan seperti kelebihan beban dan hubung singkat. Pengendalian dari sistem proteksi sendiri harus cepat dan sensitif dalam merespon gangguan, sehingga langsung memerintahkan sistem proteksi untuk bekerja. Dalam penelitian ini dibuat prototipe proteksi arus lebih terdiri dari komponen seperti Tranformator Arus, Mikrokontroller ATmega32, pengkondisi sinyal, lcd 2x16, ULN 2003, relay, dan komponen pendukung lainnya. Diperlukan pengkalibrasian system, supaya tidak terjadi kesalahan pada proses pengamanan saluran, kesalahan pembacaan sensor sebesar 0.01553% pada saat pengujian tranformator arus 1, pada saat pengujian tranformator arus 2 kesalahan pembacaan alat sebesar 0.019495% , sedangkan pada saat pengujian sensor tegangan kesalahan pembacaannya 0.001459%. Pada masing-masing Tranformator arus dibatasi arus maksimal 4 ampere. Apabila terjadi arus lebih dari batas maksimal arus yang ditentukan, maka sistem proteksi akan memutus saluran dan menghubungkan kembali apabila arus dibawah batas maksimal. Kata kunci –Transformator Arus, Mikrokontroller ATmega32, ULN 2003 dan Relay. Abstract -Protection systems in electric power equipment is needed to maintain reliability and power quality, The good protection system capable to alocate overload and short circuit. System control of the protection system must be fast and sensitive in responding of fault thus directly ordered protection system to work. In this research a prototype overcurrent protection consists of components such as transformers Flow, ATmega32 microcontroller, signal conditioning, lcd 2x16, ULN 2003, relays, and other supporting components. In this thesis required calibration system, so that won’t give error occurs in the process of securing the channel, the sensor reading error of 0.01553% when the current transformer testing 1, when the current transformer testing tool 2 reading errors by 0.019495% and then testing error voltage sensor reading is 0.001459%. For each of the current transformers is limitedmaximum current4 amperes. If there is more current than the maximum current limit isspecified, the protection system will be disconnected and reconnected when the channel below the current maximum limit. Keywords– Current transformer, microcontroller ATmega32, ULN 2003 and Relay.

Item Type: Article
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik (FT) > Prodi Teknik Elektro
Depositing User: Herri Gusmedi
Date Deposited: 17 Feb 2020 03:43
Last Modified: 17 Feb 2020 03:43
URI: http://repository.lppm.unila.ac.id/id/eprint/17471

Actions (login required)

View Item View Item